Functions and parameters
Operation and connection sequences
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
Event: 18. Ergo cabin, tilt up
Previous event 12. Fork lift
Action(s) –
Contributing factors Factory parameter 1104: Permitted cabin tilting.
Factory parameter 1259: Calibration, Ergo cabin up
Resulting conditions Output T2-K1:10 “OUT.(PWM) CABIN TILT UP” reduces the voltage.
The proportional valve [Q11] opens in proportion to the voltage applied
to it.
The cabin tilt cylinder is pressurised.
Event: 18. Ergo cabin, tilt down
Previous event 13. Fork lowering
Action(s) –
Contributing factors Service parameter 355: Offset, cabin tilting down
Factory parameter 1104: Permitted cabin tilting.
Factory parameter 1260: Calibration, Ergo cabin down.
Resulting conditions Output T2-K1:2 “OUT.(PWM) CABIN TILT DOWN” reduces the voltage.
The proportional valve [Q21] opens in proportion to the voltage applied
to it.
The cabin tilt cylinder is drained to the tank.
Event: 19. Logout
Previous event 2. Login.
Action(s) The operator presses the red button.
Contributing factors –
Resulting conditions The login screen is displayed and login is possible.
The screen to be displayed is determined by service parameter 503.