4 42 Repair Manual RRE140/160/180/200/250 © BT
Functions and parameters
Operation and connection sequences
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
Event: 18. Ergo cabin, tilt up
Previous event 12. Fork lift
Action(s)
Contributing factors Factory parameter 1104: Permitted cabin tilting.
Factory parameter 1259: Calibration, Ergo cabin up
Resulting conditions Output T2-K1:10 “OUT.(PWM) CABIN TILT UP” reduces the voltage.
The proportional valve [Q11] opens in proportion to the voltage applied
to it.
The cabin tilt cylinder is pressurised.
Event: 18. Ergo cabin, tilt down
Previous event 13. Fork lowering
Action(s)
Contributing factors Service parameter 355: Offset, cabin tilting down
Factory parameter 1104: Permitted cabin tilting.
Factory parameter 1260: Calibration, Ergo cabin down.
Resulting conditions Output T2-K1:2 “OUT.(PWM) CABIN TILT DOWN” reduces the voltage.
The proportional valve [Q21] opens in proportion to the voltage applied
to it.
The cabin tilt cylinder is drained to the tank.
Event: 19. Logout
Previous event 2. Login.
Action(s) The operator presses the red button.
Contributing factors
Resulting conditions The login screen is displayed and login is possible.
The screen to be displayed is determined by service parameter 503.