EasyManua.ls Logo

btsr MATRIX CUBE - Page 104

Default Icon
129 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIAPER FEEDER Device
MATRIX CUBE - 84 -
P1.3
TIME ALARM
Time during which the tension value may exit from the tolerance band set by the
previous parameter (ERROR TENSION). You can disable (OFF) this feature by
holding the Enter button pressed for 3 seconds.
[Allowed values 0.0
(*)
÷ 10 seconds].
(*) Setting 0.0 activates the AUTO mode; this means that the system will
automatically calculate the best alarm generation and machine stop time,
depending on the feeding speed. At low speed, such time is 500 ms; as the
speed increases it will be reduced up to a minimum of 50 ms; this allows a
quick machine stop during normal operation avoiding, however, the risk of
false stops when working at low speed.
Choose the desired value using:
(to increase the value) or (to decrease the value).
to confirm.
Example: Main Tension: 2.0 g
Error Tension: ± 0.5 g
Time Alarm: 2.0 sec.

Table of Contents

Related product manuals