DIAPER FEEDER Device
MATRIX CUBE - 77 -
3) Exclusion and Re-inclusion of a DIAPER FEEDER Device
When needed, it is possible to temporarily exclude a DIAPER FEEDER device, in
order to avoid undesired starts due to vibrations, etc. To exclude and re-include a
device, operate as follows:
Exclusion:
Press and hold down for 3 seconds
:
The display will show the exclusion confirmation request.
to confirm the exclusion
.
to cancel the operation
.
The <<OFF>> indication, shown on display indicates that the device is
currently excluded.
Re-inclusion:
To re-activate the device press and hold down for 3 seconds
.
to confirm the re-inclusion
.
to cancel the operation
.
In order to temporarily de-activate a DIAPER FEEDER device simply press
. The condition of device temporarily de-activated is signaled by the
lighting the red LEDS inside the 3 push-buttons and inside theTS44 tension
sensor.
4) Control of Temperature and Current Absorbed by DIAPER FEEDER
At any time, pressing the button, you can check the internal temperature (T)
of the control board (32°C in the example below) and of the motor (31°C in the
example below), as well as the current absorbed by the motor (C) in Ampere (0.1 A
in the example below).