10.3.5.3 0x2101 Locating function
Sub-
index
Name Description
Access type
Data type
Data memory
Factory
reset
0x1 Locating function Activate or deactivate locating function:
This function enables a device in the
system to be located using the PLC. The
topLEDindicatorwillbrieystarttoash
when the locating function is activated
(fastashingLEDs)
0 = activated
1 = deactivated
RW UINT8
Table 11: 0x2101 Locating function
10.3.5.4 0x2120 LED mode
Sub-
index
Name Description
Access type
Data type
Data memory
Factory
reset
0x0 LED mode Select LED indicator mode
Please refer to the chapter “Device
status indicator” of the operating instruc-
tions for a description of the possible
indicator modes
0: NAMUR mode
1: Valve mode (signal open/closed),
no errors
2: Valve mode + errors (red)
3: Valve mode + errors (red)
+ warnings (yellow, blue orange)
4: External color mode
(denedinindex0x2122)
5: LED demo
6:LEDo
RW UINT32 x x
Table 12: 0x2120 LED mode