Technical data
36
Translation of the Original Operating Manual
V-MIX Fix Plus
3.5 Capacity limits
The specific weight of the processed material must not exceed 500 kg per m³.
3.6 Operating fluids
Oils/greases used
Gear oil
ISO VG 150
SAE 80/W85
API GL5
DIN 51512
Hydraulic oil
ISO VG 46
HLP
DIN 51524 T2
Lubricating grease
Multi-purpose grease
Lithium-saponified grease
NLGI 2
DIN 51502
Gear oil
ISO VG 320
SH 320
DIN 51506 VDL
BVL Farmgrease
NSF-H1
ISO 21469
3.7 Information on noise generation
The sound pressure level generated by the machine is less than 70 dB(A). This measurement was taken
in an assembly hall without nearby equipment at a distance of approx. 5 m.