6.2 Starting and ending the mixing process
1. Set the “Mix/Deliver” selector switch at the control switch cabinet to the “Mix” position (see chapter
”Operating elements and controls“, page 52).
2. Set the mixing time on the “Main screen” of the control panel (see chapter “Display”, page 53).
3. Close the dosing gate by pressing the button “3, 4 or 5“ at the control switch cabinet (see chapter
“Operating elements and controls”, page 52).
4. Set the “1” selector switch at the control switch cabinet to the “On” position (see chapter “Operating
elements and controls”, page 52).
The start-up warning will beep for 10 seconds before the mixing auger starts up.
The mixing auger slowly revs up to the preset speed.
To prevent overload, the mixing auger will rotate in the opposite direction for 2 sec-
onds during start-up.
5. To end the mixing process, allow the preset time to elapse or set the “1” selector switch at the
control switch cabinet to the “Off” position (see chapter “Operating elements and controls”, page
52).
The mixing process has ended.