Design and function
V-MIX Fix Plus
Translation of the Original Operating Manual
47
4.12 Hydraulic unit (optional)
A hydraulic unit is used to perform such hydraulic func-
tions as opening and closing the dosing gate. Operation
requires that all individual hydraulic components of the
machine be connected to the electrohydraulic control
block (3) of the hydraulic unit.
The hydraulic functions are performed using the operat-
ing buttons at the control switch cabinet (see page 52).
The hydraulic system is switched on when a discharge
gate or an elevator is activated and is switched off again
automatically after approx. 30 seconds.
Overview of hydraulic assemblies:
Motor (1),
Oil tank (2),
Electrohydraulic control block (3)
Fig. 4-22
4.12.1 Electrohydraulic control block
(1) Open dosing gate
(2) Close dosing gate
(3, 4) Optional for controlling an additional dosing gate
or conveyor belt.
(5) Bypass valve
Fig. 4-23
3
1
2
2
5
4
1
3