Translation of the Original Operating Manual
8 Faults
Risks of personal injury from crushing, shearing, cutting, amputation, entrapment,
winding up, entanglement, catching and impact may arise if the machine starts up
inadvertently.
Secure the machine against inadvertent start-up before troubleshooting it.
Wait until the machine has come to a complete stop before entering the danger area.
Mixing auger not rotating
Replace the coupling.
Also observe the operating manu-
als provided by the suppliers.
Check and, if necessary, replace
the gear unit.
Also observe the operating manu-
als provided by the suppliers.
Replace the shaft.
Also observe the operating manu-
als provided by the suppliers.
Consult a trained electrician who is
able to find the cause of the power
failure and to correct it.
Consult a trained electrician who
will replace the power cable.
Weighing unit showing incorrect
values
The weighing computer is incorrect-
ly adjusted
Check the settings of the weighing
computer; for this purpose, refer to
the operating manual for the weigh-
ing unit.
Check screw connections of com-
ponents for tight fit.
The plug connector is dirty
Clean and dry the plug (do not use
contact spray).
Electrical control system
Error in the electrical control system
Observe the operating manuals