19
【command】
showntp‐servicesession
【view】 configview
【parameter】
【description】
ViewtheOLTNTPsessioninformation.
clocksource:TheclockserverIPaddress.
【example】
ViewtheOLTNTPsessioninformation
OLT(config)#showntp‐servicesession
clocksource:202.120.2.101
clockstratum:3
clockstatus:configured,
sane
referenceclockID:79.213.241.147
reach:1
currentpoll:32
now:0
offset:+511298392.149292ms
delay:0.135728
disper:3.939436
4.11timezone
【command】
timezone(gmt+timezone|gmt‐timezone)
【view】 configview
【parameter】
gmt+:Theeasterntimezone
gmt‐:thewesterntimezone
timezone
:
timezone,formatishh:mm,maximunoftheesterntimezoneis18:00,maximunofthe
westerntimezoneis18:00。
【description】
Configuretheesterntimezoneorthewesterntimezoneofsystem.“GMT+”representtheestern
timezone,justaslocaltimefaster than Greenwichmeantime,“GMT‐”representthe
western
timezone,justaslocaltimeslowerthanGreenwichmeantime。
【example】
SetthecurrentsystemtimezonetoGMT+7:00
OLT(config)#timezonegmt+08:00
4.12showtimezone

Table of Contents