59
aclid:SpecificACL
all:ShowalloftheACL
Desctribtion
Example
QueringalloftheACLinformationaboutdevices
OLT(config)# show acl all
Basic ACL 2000, 1 rules hold
rule 1 permit source 10.10.10.2 0.0.0.0 time-range working-day
12.QOS
12.1packetfilter
Commond
packetfilter(inbound|outbound)aclid[ruleidruleid]portge|EPON|xgeportlist
nopacketfilter(inbound|outbound)aclid[ruleidruleid]port ge|EPON|xgeportlist
View
Configview
Parameter
Inbound:
Thetrafficoninboundpacketsoftheinterface
Outbound the
traffic on outbound packets of the interface
ruleid
theruleIDofACL
aclid: ACLsname
portlist
portslist
Describtion
packet-filter: This commond is used to config ALC filter rules for special port,and make it
effect.you can use this commond , when you need to use the ACL rules to filter on port traffic.
no packet-filter: This commond is used to cancel the designated port of ACL filtering rules.
When you need to delete the specified port acls to filter rules, use this command.
Example
In the worktime period, specified port 1 can only receive message from IP address for 10.10.10.2
OLT(config)#timerangeworktime8:00to18:00workingday
OLT(config)#acl2000
OLT(aclbasic2000)#rule2permitsource10.10.10.20.0.0.0timerangeworkingday
OLT(aclbasic2000)#rule1denysourceanytimerangeworkingday
OLT(aclbasic2000)#
exit
OLT(config)#packetfilterinbound2000portge1