E602-0006-- Firmware error
Detection Description Loading of Subbootable ends in failure.
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
E602-0007-- Firmware error
Detection Description Damage on the internal file
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
E602-0008-- The memory area in the Main Controller is depleted
Detection Description Remaining memory area in the Main Controller is small.
Remedy
* Turning OFF and then ON the main power stops the error code to be displayed, but the continuous
use causes the memory area in the Main Controller PCB to be completely used up or causes
symptoms such as machine freeze.
1. Replace the Main Controller PCB.
E602-0009-- MEAP cannot be started.
Detection Description MEAP cannot be started due to an error caused by invalid power down.
Remedy
1. Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main
power.
* Since the installed MEAP application and its management information are all cleared after reboot,
MEAP needs to be reinstalled.
E602-1102-- File system could not be initialized normally. (MEAP-related)
Detection Description File system could not be initialized normally.
Remedy
1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be
displayed in some cases, execute the remedy for E616-0001.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1112-- Device access error (MEAP-related)
Detection Description Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be
displayed in some cases, execute the remedy for E616-0001.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1113-- Device access error (MEAP-related)
Detection Description Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be
displayed in some cases, execute the remedy for E616-0001.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1302-- File system could not be initialized normally.
Detection Description File system could not be initialized normally.
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1312-- Device access error
Detection Description Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1313-- Device access error
Detection Description Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
8. Error/Jam/Alarm