Service Mode > LOG GR.
DEBUGLOG-SW ON/OFF of debug log auto output
Detail To set whether to perform sublog auto output when error code/service call has occurred.
Adj/Set/Operate Method
Select the item, and then press OK key.
Display/Adj/Set Range
Off/On
Off: Not output automatically
On: Output automatically
Default Value
Off
Supplement/Memo
Basic procedure:
[A] When setting manually (LUI)
1. Insert a USB flash drive.
2. Set the service mode [USB-H] to ON.
3. Set the service mode [DEBUGLOG-SW] to ON.
4. After error occurrence, record the debug log from menu (LUI) to the USB drive.
5. Shut down the machine.
[B] When remotely setting from RDS
1. Insert a USB flash drive.
2. Set the service mode [DEBUGLOG-SW] to ON from RDS.
3. After error occurrence, the debug log is recorded into the USB drive.
4. Shut down the machine.
DEBUGLOG-MODE File setting for debug log save
Detail To select a file to delete when saving a debug log file.
Adj/Set/Operate Method
1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
Mode 1/Mode 2
Mode 1: The file name of the debug log is fixed. If the number of debug logs exceeds the maximum
number that can be stored after a new debug log is saved, the latest debug log file is deleted to
save the new file.
Mode 2: The file name of the debug log is one with a device serial number and time stamp. If the
number of debug logs exceeds the maximum number that can be stored after a new debug log is
saved, the oldest debug log file is deleted to save the new file.
Default Value
Mode 2
PANEL LOCK GR.
Service Mode > PANEL LOCK GR.
PANEL LOCK ON/OFF of control key restriction
Detail To enable/disable the access restriction on the Control Panel keys.
Adj/Set/Operate Method
Select the item, and then press OK key.
Display/Adj/Set Range
Off/On
Off: Disable the panel lock function
On: Enable the panel lock function
Default Value
Off
F/W UPDATE GR.
Service Mode > F/W UPDATE GR.
USB Not in use
NETWORK Not in use
USB STORAGE Not in use
9. Service Mode
225

Table of Contents