Quick Startup
Setting quick startup reduces the time from when the Power Switch is pressed until screen operation becomes possible.
When the quick startup is set, pressing the Power Switch to turn off the power enables quick startup the next time the power is
turned on (quick off).
NOTE:
The quick startup function can be set from the following menu.
Setup > Control Menu > Main Pwr Quick Start
[ON]: Quick startup is executed.
[Off]: Quick startup is not executed (default).
The power supply to the PCBs depends on whether the quick startup function is ON or OFF as follows:
PCB name Power supply status
Quick startup setting ON (quick off) Quick startup setting OFF
Low Voltage Power Supply PCB Power is supplied Power is supplied
Main Controller PCB Power is supplied OFF
CAUTION:
Prohibited items when quick off
Disconnecting the power plug from the outlet
Inserting and removing an SD card
Installing and removing the Duplex Unit
Installing and removing pickup options
Never do any of the above in quick-off mode as doing so will cause an engine failure, controller PCB failure, MEAP data
damage, etc.
In quick-off mode, be sure to perform a shutdown as described below and then disconnect the power plug from the outlet
and perform the work.
Reset > Shut Down > Yes
A shutdown can be performed by pressing the Main Power Switch for at least 5 seconds, but this is not recommended
because the power may be turned OFF before the MEAP shutdown process completes.
Note that under the following conditions (settings), the machine always starts up normally (even if quick startup is ON).
At first startup after the power plug is connected to the outlet
When the network-related settings are configured as follows:
Setup > Network > TCP/IP Settings > IPv6 Settings > On
Setup > Network > TCP/IP Settings > IPv4 Settings > Protocol > Use BOOTP > ON
Setup > Network > TCP/IP Settings > IPv4 Settings > Protocol > Use RARP > ON
When IPSec is set
MEAP-related Information
During execution of an MEAP application which prohibits quick startup
When a login application is switched by SMS
When a job is being executed (including internal jobs in progress such as calibration or cleaning)
During import of setting values using service mode or RUI
When the menu setting values are changed using remote UI or the Operation Panel
Others
When the Main Power Switch is pressed for at least 5 seconds
When an error code or a jam occurs
When a cover is open
When the accumulated time during which the machine is powered ON as well as powered OFFF (with quick startup
turned ON) is 110 hours or more.
When a system option license is registered