■ Fixing Assembly failure detection
Overview
When the machine is under the following conditions, the DC Controller shuts down the power supply to the Fixing Assembly and
notifies an error.
• Fixing temperature rising error
• Abnormally high fixing temperature detection
• Fixing drive circuit error
Description
Fixing temperature rising error
Temperature of the thermistor does not rise although a specified period of time has passed since the heater was turned ON.
Abnormally high fixing temperature detection
When a Thermistor reaches a certain temperature or higher, it is judged as abnormal high temperature for the thermistor.
Fixing drive circuit error
Error in either the Fixing Heater or the Main Motor
Error Code
• E000-0000 : Fixing temperature rising error
• E001-0000 : Abnormally high fixing temperature 1
• E004-0000 : Fixing Drive Assembly circuit error
2. Technical Explanation (Device)
35