Chapter 7  
7-32
4. FAQ
T-7-45
5. Troubleshooting
T-7-46
No. Question Answer
Q1 Registration information of the device (E-RDS) is once 
deleted from the UGW server, and is re-registered after that. 
If a communication test is not
carried out, then device information on UGW becomes 
invalid.
When registration of the device (e-RDS) is deleted from the 
UGW, the status will be changed to that the communication 
test has not completed because related
information has lost from a database. Therefore, device 
information will also become invalid if that condition is going 
for seven days without carrying out the communication
test. Hence, to avoid the invalid condition, carry out the 
communication test.
Q2 The communication test with the UGW server results NG! The following cases can be considered in the becoming NG 
case.
- 1. Name resolution was failed due to an incorrect host name 
or DNS server has been halted.
- 2. Network cable is blocked off. Network cable is broken.
- 3. Proxy server settings are not correct.
Q3 Could you describe the timing of data transmitting from the 
device (e-RDS) to the UGW, and what data size is sent to the 
UGW?
The schedule of data transmitting, and the start time are 
determined by settings in the UGW side. The timing is once 
per 16 hours by default, and counter data size
could be maximum 1400 bytes.
Q4 Can I turn the device power off during the device (e-RDS) 
operation?
While operating the device (e-RDS), the power of the device 
must be ON. If power OFF is needed, do not leave the device 
power OFF for long time. It will
become "Device is busy, try later" errors if the power supply 
of network equipment such as HUB is made prolonged OFF.
No. Condition detected Action
1 The communication test has failed. Check network conditions such as proxy server settings and so on.
- Check the communication log from COM-LOG. -> Execute "Remedy" in the "Error 
message list".
- Check whether RGW-ADDRESS or RGW-PORT settings have changed.