62-61753-21     
The unit is in Service Mode, and the refrigeration system is ready to 
be evacuated then charged with refrigerant. Refer to Section 5.1.3. 
Pretrip has been aborted either by user or by a pretrip alarm. 
Service  Mode has been turned off and unit is returning to normal 
operation. 
The = key was not pressed in the allotted amount of time to select the 
new Functional Parameter setting. The new setting was not stored 
and the old setting will be used. 
Indicates that no changes have been made to the hourmeters in ei-
ther the Configuration or functional parameter lists. 
INACTIVE ALARMS IN MEMORY 
There are inactive alarms in the microprocessor alarm list which have 
not yet been cleared. 
INSTALLED, REMOVE CARD XX 
An Option PC Card has been inserted into the PC Card slot, and the 
option has been installed in the microprocessor. The PC Card may 
safely be removed from the slot. XX indicates the number of option 
installations remaining on card. 
INSTALLING OPTION, PLEASE WAIT 
An Option PC Card has been inserted into the PC Card slot, and the 
option is being installed in the microprocessor. DO NOT REMOVE 
THE CARD WHILE THIS MESSAGE IS BEING DISPLAYED. 
INSTALL STOPPED, REINSERT CARD 
An Option PC Card has been inserted into the PC Card slot, and the 
install process has been stopped by the PC Card not being fully in-
serted in the slot, or by being removed. Remove and reinsert PC 
Card to continue. 
The IntelliSleep IntelliSet is active. This message alternates with 
"CHANGE INTELLISET TO EXIT" at 5 second interval whether unit is 
running or not 
KEYPAD LOCKED-BATTERY TOO LOW 
Once the battery voltage goes below 7.0 Volts for 10 seconds, all of 
the keys on the keypad will be locked. 
LIST END, = TO CLEAR ALARMS 
The end of the Alarm list has been reached. Pressing the = key will 
clear the Alarm list. 
A Configuration PC Card has been inserted into the PC Card slot, 
and information from the Configuration card is being loaded into the 
microprocessor.  DO NOT REMOVE THE CARD WHILE THIS MES-
SAGE IS BEING DISPLAYED. 
Consists of Configuration Mode, Component Test and Service 
Modes. 
MAX SETPOINT HAS BEEN REACHED 
Maximum set point allowed by Configuration settings has been 
reached. 
MICRO WILL RESET & RESTART NOW 
The microprocessor Program software has just been changed, or a 
new Configuration has been programmed into the microprocessor.  
The microprocessor will turn itself off then on again (similar to a com-
puter reboot) in order for the changes to be effective. 
MICRO WILL STOP IN XXX SECONDS 
The START / RUN-OFF switch has been turned OFF and the system 
valves are closing. The display will turn off when the count down 
reaches zero. 
MIN SETPOINT HAS BEEN REACHED 
Minimum Set Point allowed by Configuration settings has been 
reached. 
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and one or more of 
its settings have been modified. 
NEW SW: = TO LOAD,  TO   CANCEL 
A Program PC Card has been inserted into the PC Card slot, and the 
program on the PC Card is a newer version than what is already 
loaded in the microprocessor. Press the = key to load the program.