4-OPERATINGINSTRUCTIONS
7.Placetheswitch(1)inthelockedposition.Theaudible
alarmdevicewillceasefunctioning.(Refertopage
“3-53”)
SMIL15CEX0960AB7
8.Maintainthepressureinthebucketcylindertoallow
thelatchinghooktoclose.Raisetheattachmentso
youcanseethebucketpin.
CT02C209TBP18
9.Makesureyoucanseethatthebucketpiniscorrectly
engagedinthelatchinghook.
NOTE:Ifitisnotpossibletomakeavisualchecksitting
intheoperator'sseat,getdownfromthemachineand
makesurethatthetooliscorrectlyconnectedwiththe
safetydeviceengaged.
TX8XZ1-008A9
10.Operatethebucketcontroltoretractthecylinderrod
andallowthesafetydevicetoengage.
TX8XZ1-009A10