6-MAINTENANCE
Cleaningandreplacingthesuctionlter
1.Releaseallpressureinthehydraulicreservoir.See
"releasingpressureinthehydraulicsystem".
2.Cleanthetopofthehydraulicreservoirandcleanthe
inletscreencover.
SMIL15CEXX749AA6
3.Removethecover(1),O-ring(2)andspring(3)onthe
topoftheinletscreenrodassembly.
4.Removethelter(4)andcleanwithsolvent.Dryit
completelyandcheckitforanydamage.Ifthereis
anydamageonthesurface,replaceitwithanewone.
5.InstallanewO-ring(2)andinstallthelter(4),spring
(3)androdassembly.
6.Installthecover(1).
7.Checkthelevelofthehydraulicuidandaddmoreif
necessary.See"llingthereservoir".
NOTE:Installanewinletscreenevery5000hoursofop-
erationorwhenthehydraulicuidischanged.
SMIL15CEXX752BB7
6-39