6-MAINTENANCE
Batteriesaccess
Toaccessthebatteries,opentheleft-handreardoorthen
removetheskidplate.
SMIL15CEXX790AA1
Checkingthechargestateofamaintenancefreebattery
Thechargeindicatoronthebatteryshowsthestateof
chargeofthebattery.
Ifthecoloris:
Green;thechargeiscorrect.
Black;insufcientcharge.Rechargethebatteryuntilthe
indicatorturnsgreen.
Transparent(colorless);replacethebatteryassoonas
possible.
SMIL15CEXX791AA2
Checkingtheelectrolytelevelofamaintenancetypebattery
Removethecellcapsandcheckthelevelineachbatteries
cell.Thelevelshouldbebetween10mm(0.4in)and
15mm(0.6in)abovetheplates.Adddistilledwaterif
necessary,theninstallthecellcaps.
NOTE:Whenaddingdistilledwaterattemperaturesbe-
low0°C(32.0°F),thebatteriesmustbechargedorthe
enginerunfortwohoursapproximatelyinordertoen-
surethatthedistilledwaterandtheelectrolyteareprop-
erlymixed.
NOTE:Makesurethebatteryterminalsarecleanand
coatedwithgreaseandthatthecablesareproperlytight-
ened.
9K4QUU-001A3