3-CONTROLSANDINSTRUMENTS
DonotpresstheDPDswitchifmanualregenerationshouldnotbeperformed.
Theorangelampstopsashingafter10s.
1.Automaticregenerationisperformed.
ThegreenDPDlamplightsup.
Thefollowingmessageisdisplayed.
AutoDPDRe-gen
2.PresstheDPDswitch.
3.Automaticregenerationisstopped.
ThegreenDPDlampgoesout.
Thefollowingmessageisdisplayed.
PushDPDswitchtoactivate
4.Movethemachinetoasafelocationwherethereisnothingthatcouldcatchare,thenputthegateleverintothe
lockposition(stored).
5.Toshifttomanualregeneration,holddownuntiltheorangeDPDlamplightsup.(3s)
6.Itshiftstomanualregeneration.(Thelampchangesfromlittoashing.)
TheorangeDPDlampashes.
Thebuzzersoundsfor2s.
Thefollowingmessageisdisplayed.
7.Whilethelampisashing(10seconds),presstheDPDswitch.(DonotpresstheDPDswitchifmanualregener-
ationshouldnotbeperformed.Thelampgoesoutafter10s.Thefollowingmessageisdisplayedagain.)
PushDPDswitchtoactivate
8.Manualregenerationstarts.
TheorangeDPDlamplightsup.
Thebuzzersoundsfor2s.
Thefollowingmessageisdisplayedinrotation.
ManualDPDRe-gen
Donotoperate
Regenerationtime:20-25minutes
9.Manualregenerationends.
TheDPDgaugegoesto0.
TheDPDlampgoesout.
3-44