Application of Interface
When into this screen is entrance to the judgment setting of transformer balance, it is also
guidable operation, just according the block area on the screen and number keys to input the
pin number, press [ENTER] then automatically change to next pin setting item, use the same
method till the last item of pin number on the same screen, press [ENTER] then automatically
change to next the setting screen of parameter.
Ex.: The pin of the testing transformer two items balance are following:
L1(PIN 1 – 2) = 1.750 mH, L2(PIN 3 – 4) = 1.750 mH
Standard = 1.750 mH, ABS (L1 – L2) < 1%
Then the input is as below:
Press the unit key [unit : uH] beside the screen to change the unit to The mH in back-light.
NOMINAL VALUE : [1] [.] [7] [5] [Enter]
BALANCE – L1 : [0] [Enter]
BALANCE – L2 : [1] [Enter]
ABS (L1 - L2) < : [1] [Enter]
After finish the input all the parameter, the screen is as below:
Press [ENTER] again then enter next setting screen as below : (CAPACITANCE)