Remote Operation
4-7
*RST Reset Command
Type: Device State
Description: This command forces an ABORt, *CLS, LOAD=PROT=CLE
command and sets the parameters to factory default.
Setting Syntax: *RST
Setting Parameters: nil
*SAV Save Command
Type: Device Status
Description: This command stores the present state of the single electronic load
and all channel states of multiple loads in a specified memory
location.
Setting Syntax: *SAV<space><NR1>
Setting Parameters:<NR1>, 1 ~ 10
Setting Example: *SAV 5
*SRE Service Request Enable Command/Query
Type: Device Status
Description: This command sets the condition of the Service Request Enable
register to determine which event of the Status Byte register (see
*STB) is allowed to set the MSS (Master Status Summary) bit. A "1"
in the bit position is logically ORed to cause the Status Byte register
Bit 6 (the Master Summary Status Bit) to be set. See details
regarding the Status Byte register in Chapter 5.
Setting Syntax *SRE<space><NR1>
Setting Parameters:<NR1>, 0 ~ 255
Setting Example: *SRE 20 Enable the CSUM and MAV bit for Service Request.
Query Syntax: *SRE?
Return Parameters:<NR1>
Query Example: *SRE? Return current setting for "Service Request Enable".
*STB? Read Status Byte Query
Type: Device Status
Description: This query reads the Status Byte register. Note that the MSS
(Master Summary Status) bit instead of RQS bit is returned in Bit 6.
This bit indicates if the electronic load has at least one reason for
requesting service. *STB? does not clear the Status Byte register,
which is cleared only when subsequent action has cleared all its set
bits. Refer to Chapter 5 for more information about this register.
Status Byte Register
Bit Position
7
6
5
4
3
2
1
0
Condition
0
MSS
ESB
MAV
QUES
CSUM
0
0
Bit Weight
128
64
32
16
8
4
2
1
Query Syntax: *STB?
Return Parameters:<NR1>
Query Example: *STB? Return the contents of "Status Byte".
Return Example: 20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200A Series and is the answer not in the manual?

Chroma 63200A Series Specifications

General IconGeneral
BrandChroma
Model63200A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals