High Power Electronic Load 63200A Series Operation & Programming Manual
2:OCP TEST FAIL-L
3:GONG TOTAL PASS-H
4:GONG TOTAL FAIL-L
5:OTP OVP OCP OPP REV-H
6:BUS CTRL. ACT-H
7:BUS CTRL. ACT-L
Setting Example: CONF:DIO:OUT1 2 Set DO1 to OCP TEST FAIL-L.
CONF:DIO:OUT1 0 Set DO1 to NONE.
Query Syntax: CONFigure:DIO:OUT1?
Return Parameters: <NR1>, 0 ~ 7 [Unit = None]
Query Example: CONF:DIO:OUT1?
CONFigure:DIO:OUT2
Type: Frame-Specific
Description: Set the DO2 type the pin No.9 in System I/O Port.
Setting Syntax: CONFigure:DIO:OUT2<space><NR1>
Setting Parameters: <NR1>, 0 ~ 7
0:NONE
1:OCP TEST PASS-H
2:OCP TEST FAIL-L
3:GONG TOTAL PASS-H
4:GONG TOTAL FAIL-L
5:OTP OVP OCP OPP REV-H
6:BUS CTRL. ACT-H
7:BUS CTRL. ACT-L
Setting Example: CONF:DIO:OUT2 1 Set DO2 to OCP TEST PASS-H.
CONF:DIO:OUT2 0 Set DO2 to NONE.
Query Syntax: CONFigure:DIO:OUT2?
Return Parameters: <NR1>, 0 ~ 7 [Unit = None]
Query Example: CONF:DIO:OUT2?
DIO:OUT1
Type: Frame-Specific
Description: It sets the system I/O port pin 8 DO1 status when the BUS CTRL.
mode is selected for DO1.
Setting Syntax: DIO:OUT1<space><NR1>
Setting Parameters: <CRD | NR1>, OFF(0), ON(1)
Setting Example: DIO:OUT1 ON Set DO1 to act.
DIO:OUT1 0 Set DO1 not to act.
Query Syntax: DIO:OUT1?
Return Parameters: <CRD>, OFF, ON [Unit = None]
Query Example: DIO:OUT1?
DIO:OUT2
Type: Frame-Specific
Description: It sets the system I/O port pin 9 DO2 status when the BUS CTRL.
mode is selected for DO2.
Setting Syntax: DIO:OUT2<space><NR1>
Setting Parameters: <CRD | NR1>, OFF(0), ON(1)
Setting Example: DIO:OUT2 ON Set DO2 to act.
DIO:OUT2 0 Set DO2 not to act.
Query Syntax: DIO:OUT2?