EasyManuals Logo

Chroma 63200A Series User Manual

Chroma 63200A Series
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
High Power Electronic Load 63200A Series Operation & Programming Manual
4-28
Setting Example: BATT:ENDV 0.5 Set end voltage = 0.5V
BATT:ENDV 500mV Set end voltage = 0.5V
BATT:ENDV MAX Set end voltage = maximum value.
BATT:ENDV MIN Set end voltage = minimum value.
Query Syntax: [ADVance:]BATTery:ENDVoltage?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example: BATT:ENDV?
BATT:ENDV? MAX
BATT:ENDV? MIN
[ADVance:]BATTery:TOUT
Type: Channel-Specific
Description: Set timeout for battery discharge mode.
Setting Syntax: [ADVance:]BATTery:TOUT<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0s~100000s, Resolution = 1s, Unit = Second
Setting Example: BATT:TOUT 100 Set timeout = 100s
BATT:TOUT MAX Set timeout = maximum value.
BATT:TOUT MIN Set timeout = minimum value.
Query Syntax: [ADVance:]BATTery:TOUT?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example: BATT:TOUT?
BATT:TOUT? MAX
BATT:TOUT? MIN
[ADVance:]SINE:IAC
Type: Channel-Specific
Description: Set AC current for sine wave dynamic mode.
Setting Syntax: [ADVance:]SINE:IAC<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: SINE:IAC 0.5 Set AC current = 0.5A.
SINE:IAC 500mA Set AC current = 0.5A.
SINE:IAC MAX Set AC current = maximum value.
SINE:IAC MIN Set AC current = minimum value.
Query Syntax: [ADVance]:SINE:IAC?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Ampere]
Query Example: SINE:IAC?
SINE:IAC? MAX
SINE:IAC? MIN
[ADVance:]SINE:IDC
Type: Channel-Specific
Description: Set DC current for sine wave dynamic mode.
Setting Syntax: [ADVance:]SINE:IDC<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: SINE:IDC 0.5 Set DC current = 0.5A.
SINE:IDC 500mA Set DC current = 0.5A.
SINE:IDC MAX Set DC current = maximum value.
SINE:IDC MIN Set DC current = minimum value.
Query Syntax: [ADVance:]SINE:IDC?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Ampere]
Query Example: SINE:IDC?
SINE:IDC? MAX
SINE:IDC? MIN

Table of Contents