GE+ ACDC Installation and operation manual v11
52 / 121
Parameters of
Frequency variation
Allowed range of values
Fundamental frequency of phases U,V,W Minimum frequency – Maximum frequency
FadeIn Ramp [Hz/s] 0.01-1000
FadeOut Ramp [Hz/s] 0.01-1000
Example Flicker 120% 10Hz
VIII. Creation of Fault Sequence
It is possible to create a .csv file to be introduced in the interface to create a Fault Sequence. It
can be made using an editor such as Excel or directly in the interface. This chapter explains how
to create this file via Excel. To create this file via interface is explained in chapter 9 (Human
interface).
Each row of the Excel has the parameters, separated by comas, of the fault to send:
- Voltage Dip, Over/Under Voltage.
Voltage Dip, Fault Duration, Fault Start Angle, Voltage % phase U, Voltage % phase V,
Voltage % phase W, Angle phase U, Angle phase V, Angle phase W, Ramp FadeIn,
Ramp FadeOut, Ramp angle FadeIn, Ramp angle FadeOut
Example:
Voltage Dip,100,90,200,100,100,90,30,0,100,0.1,100,0.1
Parameters of
Flicker
Allowed range of values
Voltage of fundamental harmonics of phases
U,V,W
V
RMS
± 50%
Frequency of flicker 0.01-20 Hz
FadeIn Ramp [%/ms] 0.01-1000
FadeOut Ramp [%/ms] 0.01-1000