Manually resolve the conflict by editing the full zone set, activating the corrected zone set, and then
bringing up the link.
Figure 35: Importing and Exporting the Database
Importing and Exporting Zone Sets
You can import or export the zone set information from or to an adjacent switch.
SUMMARY STEPS
1.
switch# zoneset import interface fc slot/port vsan vsan-id
2.
zoneset export vsan vsan-id
DETAILED STEPS
PurposeCommand or Action
Imports the zone set from the adjacent switch connected through
the specified interface for the VSAN or range of VSANs .
switch# zoneset import interface fc slot/port vsan
vsan-id
Step 1
Exports the zone set to the adjacent switch connected through the
specified VSAN or range of VSANs.
zoneset export vsan vsan-id
Example:
switch# zoneset export vsan 5
Step 2
Zone Set Duplication
You can make a copy and then edit it without altering the existing active zone set. You can copy an active
zone set from the bootflash: directory, volatile: directory, or slot0 to one of the following areas:
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
OL-27583-01 147
Configuring and Managing Zones
Zone Set Duplication