Releasing Zone Database Locks
To release the session lock on the zoning database on the switches in a VSAN, use the no zone commit vsan
command from the switch where the database was initially locked.
switch# configure terminal
switch(config)# no zone commit vsan 2
If session locks remain on remote switches after using the no zone commit vsan command, you can use the
clear zone lock vsan command on the remote switches.
switch# clear zone lock vsan 2
We recommend using the no zone commit vsan command first to release the session lock in the fabric.
If that fails, use the clear zone lock vsan command on the remote switches where the session is still
locked.
Note
Merging the Database
The merge method depends on the fabric-wide merge control setting:
RestrictIf the two databases are not identical, the ISLs between the switches are isolated.
AllowThe two databases are merged using the merge rules specified in the following table.
Table 21: Database Zone Merge Status
Results of the MergeMerge StatusAdjacent DatabaseLocal Database
ISLs are isolated.Successful.The databases contain zone sets with the same name.
In the enhanced zoning mode, the active zone set does
not have a name in interop mode 1. The zone set
names are only present for full zone sets but are
different zones, aliases, and attributes groups.
The adjacent database
information populates the
local database.
Failed.The databases contain a zone, zone alias, or zone
attribute group object with same name1 but different
members.
The merging of the local
and adjacent databases.
Successful.Contains data.Empty.
The local database
information populates the
adjacent database.
Successful.Empty.Contains data.
The merge process operates as follows:
The software compares the protocol versions. If the protocol versions differ, the ISL is isolated.