SUMMARY STEPS
1.
switch# show npv flogi-table [all]
DETAILED STEPS
PurposeCommand or Action
Displays the NPV configuration.switch# show npv flogi-table [all]
Step 1
Verifying NPV Examples
To display a list of devices on a server interface and their assigned NP uplinks, enter the show npv flogi-table
command on the Cisco Nexus device:
switch# show npv flogi-table
--------------------------------------------------------------------------------
SERVER EXTERNAL
INTERFACE VSAN FCID PORT NAME NODE NAME INTERFACE
---------------------------------------------------------------------------------
vfc3/1 1 0xee0008 10:00:00:00:c9:60:e4:9a 20:00:00:00:c9:60:e4:9a fc2/1
vfc3/1 1 0xee0009 20:00:00:00:0a:00:00:01 20:00:00:00:c9:60:e4:9a fc2/2
vfc3/1 1 0xee000a 20:00:00:00:0a:00:00:02 20:00:00:00:c9:60:e4:9a fc2/3
vfc3/1 1 0xee000b 33:33:33:33:33:33:33:33 20:00:00:00:c9:60:e4:9a fc2/4
Total number of flogi = 4
For each server interface, the External Interface value displays the assigned NP uplink.Note
To display the status of the server interfaces and the NP uplink interfaces, enter the show npv status command:
switch# show npv status
npiv is enabled
External Interfaces:
====================
Interface: fc2/1, VSAN: 1, FCID: 0x1c0000, State: Up
Interface: fc2/2, VSAN: 1, FCID: 0x040000, State: Up
Interface: fc2/3, VSAN: 1, FCID: 0x260000, State: Up
Interface: fc2/4, VSAN: 1, FCID: 0x1a0000, State: Up
Number of External Interfaces: 4
Server Interfaces:
==================
Interface: vfc3/1, VSAN: 1, NPIV: No, State: Up
Number of Server Interfaces: 1
To view fcns database entries for NPV edge switches, you must enter the show fcns database command
on the core switch.
Note
To view all the NPV edge switches, enter the show fcns database command on the core switch:
core-switch# show fcns database
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
64 OL-27583-01
Configuring N Port Virtualization
Verifying NPV