Applicable ModesDescriptionReason Code (long version)
AllThe small form-factor pluggable
(SFP) hardware is not plugged in.
SFP not present
AllThe physical layer link is
operational and the protocol
initialization is in progress.
Initializing
The fabric is currently being
reconfigured.
Reconfigure fabric in progress
The switch software waits for the
specified R_A_TOV time before
retrying initialization.
Offline
The interface VSAN is deleted or
is in a suspended state.
To make the interface operational,
assign that port to a configured and
active VSAN.
Inactive
A hardware failure is detected.Hardware failure
Error conditions require
administrative attention. Interfaces
may be error-disabled for various
reasons. For example:
Configuration failure.
Incompatible buffer-to-buffer
credit configuration.
To make the interface operational,
you must first fix the error
conditions causing this state and
then administratively shut down or
enable the interface.
Error disabled
The interface is isolated because
the switch is already configured
with the maximum number of
active SAN port channels.
Isolation because limit of active
port channels is exceeded.
Only E ports and TE portsThe port negotiation failed.Isolation due to ELP failure
The port negotiation failed.Isolation due to ESC failure
The Fibre Channel domains
(fcdomain) overlap.
Isolation due to domain overlap