236
Chapter 15: Configuring System Time
Defining System Time
SGE2000/SGE2000P Gigabit Ethernet Switch Reference Guide
Chapter
15
Defining System Time
The System Time Page contains fields for defining system time parameters for both the local hardware
clock, and the external SNTP clock. If the system time is kept using an external SNTP clock, and the
external SNTP clock fails, the system time reverts to the local hardware clock. Daylight Savings Time
can be enabled on the device. To define system time:
1. Click System > System Management > Time > System Time. The System Time Page opens:
System Time Page
The System Time Page contains the following fields:
Clock Source — Indicates the source used to set the system clock. The possible field values:
SNTP — Sets the system time is set via an SNTP server.
Local Settings — Sets that the system time is not set by an external source. This is the default value.
Date — Indicates the system date. The field format is Day:Month:Year, for example, 04 May 2050.
Local Time — Indicates the system time. The field format is HH:MM:SS, for example, 21:15:03.
Time Zone Offset — Indicates the difference between Greenwich Mean Time (GMT) and local time. For
example, the Time Zone Offset for Paris is GMT +1, while the local time in New York is GMT –5.
There are two types of daylight settings, either by a specific date in a particular year or a recurring
setting irrespective of the year. For a specific setting in a particular year complete the Daylight
Savings area, and for a recurring setting,
complete the Recurring area.

Table of Contents

Other manuals for Cisco SGE2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 and is the answer not in the manual?

Cisco SGE2000 Specifications

General IconGeneral
Jumbo Frame Support9KB
VLANsUp to 256
ManagementWeb-based, SNMP, CLI
StandardsIEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 802.1D, 802.1Q, 802.1p, 802.1w
Dimensions440 x 44 x 257 mm
Power Supply100 to 240V AC, 50-60 Hz
Operating Temperature0°C to 40°C
Storage Temperature-20 to 70°C (-4 to 158°F)
Humidity10% to 90% non-condensing
Weight3.2 kg