EasyManua.ls Logo

CITROEN C8 2005 - Vacuum Pump; Turbo Vacuum Regulation Electrovalve; Turbo Pressure Regulation Valve; Swirl Control Diaphragm

CITROEN C8 2005
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
202
INJECTION
CHECKING THE AIR SUPPLY CIRCUIT
Engine: 4HX
Vacuum pump.
Connect the tool [1] on the vacuum pump (3).
Start the engine.
The vacuum should be 0.8 bar at 750 rpm.
Turbo vacuum regulation electrovalve.
Connect the tool [1] between the electrovalve (2) and the valve (1).
Compare readings with the values in the table below.
Turbo pressure regulation valve.
Connect the tool [1] on the valve (1) (grey marking on pipe).
Appy a vacuum of 0.8 bar. The rod "a" should move 12 ± 2 mm.
Rod "a" should be moved 12 mm.
«Swirl» control electrovalve.
Connect the tool [1] as an adaptor between the electrovalve (4) and the control diaphragm of the «Swirl» (5).
Compare readings with the values in the table below.
«Swirl» control diaphragm.
Connect the tool [1] on the control diaphragm of the «Swirl» (5).
Apply a vacuum of approx. 0.6 bar; the pin (6) should be at the end stop, at «b».
Engine speed (rpm) Vacuum (bar)
780 0,6 bar
4000 0,25 bar
Engine speed (rpm) Vacuum (bar)
780 0 bar
4000 0,6 bar
C5
Angl.T3-page191-206-2005 4/02/05 15:05 Page 202

Table of Contents

Related product manuals