338
AIR
CONDITIONING
Interpretation of the measurements.
«m»: High pressure. «s»: Over-heating (SC).
«n»: High temperature. «t»: Ambient air temperature.
«p»: Under-cooling (SR). «u»: Blown air temperature.
«q»: Low pressure. «v»: Humidity.
«r»: Low temperature. «w»: Temperature T3.
Over-heating (SC).
The over-heating represents the difference between the aircon fluid temperature at the evaporator outlet and the
evaporation temperature.
The over-heating gives the quantity of aircon fluid (in the liquid state) in the air conditioning circuit
Values for over-heating (SC).
E5AP2FBC
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Values «p»
Origins
Solutions
< SC < 15°C
SC > 15°C
SC < 2°C
Correct quantity
Lack of aircon fluid in the cooling circuit
Excess aircon fluid in the cooling circuit
Add some
aircon fluid
Remove some
aircon fluid
Blown air temperature «u».
The blown air temperature should be between 2°C and 10°C.
Angl.T3-page322-351-2005 4/02/05 15:38 Page 338