330
AIR
CONDITIONING
Removing-refitting the drying cartridge (continued)
Unscrew the reservoir (7) (using adaptor TORX 70 FACOM).
Unscrew the reservoir (7) and the protection skirt (6).
WARNING: Components must be kept clean prior to a new reservoir being fitted.
Plug the base (10).
WARNING: Do not allow more than 5 minutes to elapse between unpacking the cartridge (reservoir (7))
and fitting it.
C5HP186C C5HP187C
C8
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Angl.T3-page322-351-2005 4/02/05 15:38 Page 330