5- 2-Wire/4-Wire LEDs
The four 2-Wire/4-Wire LEDs indicate the currently selected intercom mode for each of the two intercom channels. If either
a 2-Wire or 4-Wire connecon has been enabled for a parcular intercom channel, the corresponding 2-Wire or 4-Wire
LED indicator will be illuminated. When no intercom has been enabled, the corresponding 2-Wire or 4-Wire LED indicators
will be o.
6- IN Level Control
In Menu Mode, from the Intercom Levels screen, the IN control adjusts the incoming level of the currently selected wired
intercom channel, from the hardwired intercom system to the Tempest BaseStaon. If 2-Wire is selected the IN Level
control adjusts the incoming level of the 2-Wire signal. If 4-Wire is selected the IN Level control adjusts the incoming level
of the 4-Wire signal. If neither 2-Wire nor 4-Wire is selected the IN Level control is inacve. In addion to the intercom IN
levels, the IN control is used to adjust Aux IN levels.
7- OUT Level Control
In Menu Mode, from the Intercom Levels screen, the OUT level control adjusts the outgoing level of the currently selected
wired intercom channel, going to the hardwired intercom system from the Tempest BaseStaon. If 2-Wire is selected the
OUT Level control adjusts the outgoing level of the 2-Wire signal. If 4-Wire is selected the OUT Level control adjusts the
outgoing level of the 4-Wire signal. If neither 2-Wire nor 4-Wire is selected the OUT Level control is inacve. In addion to
the intercom OUT levels, the OUT control is used to adjust Aux OUT levels.
8- USB Connector
The USB connector is used to update the Tempest BaseStaon rmware and is not used in normal operaon.
9- Beltpack Program Connector
The Beltpack Program connector is used to pair the BaseStaon with BeltStaons. To pair the BaseStaon with a parcular
BeltStaon, ensure that the BaseStaon is powered on and in Operaonal Mode (not in Menu Mode). Ensure that the
BeltStaon is powered o. Plug one end of the pairing cable into the BaseStaon, and plug the other end of the pairing
cable into the BeltStaon. Turn the BeltStaon power on by pressing and holding the BeltStaon Power ON/OFF switch for
two seconds. The pairing process happens automacally and the message “Pairing Complete” will appear on the BeltStaon
LCD for approximately three seconds when done. Always power cycle the BeltStaon aer pairing.
10- Power ON/OFF Switch
The ON/OFF switch is used to turn the BaseStaon power (AC or DC) on and o.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clear-Com Tempest2400 and is the answer not in the manual?

Clear-Com Tempest2400 Specifications

General IconGeneral
BrandClear-Com
ModelTempest2400
CategoryIntercom System
LanguageEnglish

Related product manuals