Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–38 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Sets or returns SNMP in the form x, where:
0=Disabled
1=Enabled
COMMAND EXAMPLE: <0001/SNM=0{CR}
SNM?
Returns the unit’s nine-digit serial number in the form xxxxxxxxx.
NOTE: This query is functionally identical to RSN.
EXAMPLE: <0001/SNO?{CR}
>0001/SNO=012345678{CR}{LF}
xxxx
remote Address
Sets or returns the Physical Address in the form xxxx where:
xxxx=Address value from 0001 (DEFAULT) to 9999.
COMMAND EXAMPLE: <0001/SPA=0412{CR}
SPA?
SPA*
Community
characters, no
spaces
Sets or returns the SNMP Read Community string.
NOTE: An empty string is not allowed.
COMMAND EXAMPLE: <0001/SRC=public{CR}
SRC!
Contact
characters
Sets or returns the SNMP System Contact string.
COMMAND EXAMPLE: <0001/SSC=Joe Net Admin{CR}
NOTE: When not configured, the target returns an empty string:
SSC!
[1..128]
Interval
Sets or returns the time interval, in minutes, at which statistics are logged in the
form xx, where:
xx=interval, from 01 to 99 minutes (SEE NOTE)
Default value: 90 minutes.
COMMAND EXAMPLE: <0001/SSI=90{CR}
SSI?