60 Fault elimination
Warning Fault Message Possible causes Remedy
––– E202 CANopen Initialization of the CANopen adapter failed.
Note: The Condair RM continues to work normally. After eliminat-
ing the fault, the Condair RM must be switched off and on again to
reset the fault.
A problem occurred during
initialization of the CANopen
adapter.
Contact your Condair represen-
tative.
W204 –––
CANopenHeartbeat The clock signal of one or more components connected to the CAN
BUS is missing.
Note: The Condair RM continues to work normally.
One or more components on
the CAN BUS do not work.
Let have the CAN BUS wir-
ing between components be
checked by an electrician. Also
check if all devices on the CAN
bus are switched on.
Warning appears after a soft-
ware update.
The warning should disappear
after a few seconds. Ignore this
warning, it disappears after a
few seconds.
W205 ––– Node incompatible Unsupported component(s) connected to the CAN BUS.
Note: The Condair RM continues to work normally.
Software of one or more compo-
nents is not up to date.
Check that all components on
the CAN BUS are updated with
the latest software.
W206 ––– Update in Progress A rmware update is running.
Note: It is possible that the Condair RM may not work properly dur-
ing the update. In addition, it is possible that the RM Display truns
white during update. In this case, leave the device switched on and
wait (max. 5 minutes) until everything is working properly again.
A rmware update is in prog-
ress.
Wait until the rmware of all
components of the CAN BUS is
updated. The warning is auto-
matically reset after the update
is completed.
W207 ––– Update Failed The rmware update failed.
Note: The the Condair RM continues to work normally.
The rmware update failed. Make sure that the correct
rmware is used and restart the
update.
––– E208 Slave Master Missing A device (slave or master) on the CAN BUS can not be found.
Note: The operation of the Condair RM is stopped. Once the slave
or master is found, the system continues to run normally.
A CAN BUS participant (slave or
master) is missing.
Make sure that all CAN BUS users
are available and correctly con-
nected. Also check if all devices
on the CAN BUS are switched on.
––– E209
OTPHardware The OTP hardware code is invalid.
Note: The operation of the Condair RM is stopped. After eliminating
the fault, the Condair RM must be switched off and on again.
The hardware version which is
stored in the OTP is invalid.
Replace the control board in the
in the Condair RM.