This function allows choosing help during the indexation of the beam.
When this parameter is set to yes, during the Indexation of the beam, if the Index have not
been found, a pop-up with the instruction will appear and an interactive instruction will tell
to the operator the procedure to correctly Index the machine.
i.e. If the beam is not indexed and is actual position is upper then the Index.
When this parameter is set to yes, when a product is load from the library, or a modification
have been made in the part, it will not recalculate the axes and beam position.
When this parameter is set to yes, the down movement of the beam is stopped and the
beam is maintained in closed loop at pinch point during the retraction. The beam cycle will
resume as soon as the back gauge has finished its retraction.
This function allows choosing file destination for Parts and tools
By default the directories are in the Visitouch folder.
When set to New directory is possible to choose another folder destination i.e. if the
Numerical Control is related to the enterprise network is possible to share parts and tools
files from the same source.
Beam stop during
retractation
Indexation Aids
Disable
recalculation at
product load
Working
directories

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CYBELEC VisiPac Series and is the answer not in the manual?

CYBELEC VisiPac Series Specifications

General IconGeneral
BrandCYBELEC
ModelVisiPac Series
CategoryControl Systems
LanguageEnglish

Related product manuals