5 Command Line Interface
The D-Link DXS-1210 Series Switch allows a computer or terminal to perform some basic monitoring and
configuration tasks by using the Command Line Interface (CLI) via TELNET protocol.
To connect a switch via TELNET:
1. Make sure the network connection between the switch and PC is active.
2. To connect, launch any terminal software like HyperTerminal in Microsoft Windows, or just use the
command prompt by typing the command telnet followed by the switch IP address, e.g., telnet 10.90.90.90.
3. The logon prompt will appear.
Logging on to the Command Line Interface:
Enter your User Name and Password to log on. The default user name and password are empty. Note that
the user name and password are case-sensitive. Press Enter in both the Username and Password fields.
The command prompt will appear as shown below (DXS-1210-12TC>):
DXS-1210-12TC login:
Password:
DXS-1210-12TC>
Figure 5.1Command Prompt
The user session is automatically terminated if idle for the login timeout period. The default login timeout
period is 5 minutes. To change the login timeout session, please refer to chapter 5.
CLI Commands:
The Basic Switch commands in the Command Line Interface (CLI) are listed (along with the
appropriate parameters) in the following table.
Command Syntax Description of Usage
?
config ipif <short <1-4094>>
{ ipaddress <ip_addr> <ip_mask> |
dhcp }
config ipif <short <1-4094>>
{ipv6address <ip6_addr> <short <1-
128> | dhcpv6_client <enable |
disable>}
Configure IP setting of interface.
logout
ping [<ipv4_addr> | <ipv6_addr>] [size
<integer 1-60000>] [timeout <time_out
1-100>] [repeat <integer 0-255>]
and listens for connections. The terminal interface sends five
reboot
reset config
show ipif [<short <1-4094>>]
show ipv6 interface [<short <1-
4094>>] [brief]
Displays the current IPv6 address of the interface.
show switch
config account username <string
<32> privilege <short <1-15>>
{ nopassword | password <string
<32>}
Configure password.

Table of Contents

Other manuals for D-Link DXS-1210 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DXS-1210 Series and is the answer not in the manual?

D-Link DXS-1210 Series Specifications

General IconGeneral
Product SeriesDXS-1210
Power SupplyInternal
Jumbo Frame Support9KB
Number of Ports12
LayerL2+
Form FactorRack-mountable
Uplink Ports10G SFP+
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C

Related product manuals