xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch CLI Reference Guide
495
show cfm remote_mep
Purpose
Used to show special remote MEP’s information.
Syntax show cfm remote_mep [mepname <string 32> | md <string 22> ma <string 22> mepid
<int 1-8191>] remote_mepid <int 1-8191>
Description
This command is used to show special remote MEP’s information.
Parameters mepname – Specifies the MEP name.
md – Specifies the maintenance domain name.
ma – Specifies the maintenance association name.
mepid – Specifies the MEP MEPID.
remote_mepid – Specifies the remote MEP’s MEPID, its remote MEP is the MEP with the
above mepname.
Restrictions
None.
Example usage:
DES-3528:admin# show cfm remote_mep mepname mep1 remote_mepid 2
Command: show cfm remote_mep mepname mep1 remote_mepid 2
Remote MEPID : 2
MAC Address : 00-22-B0-7A-24-B9
Status : OK
RDI : No
Port Status Defect : Up
Interface Status Defect : No
Last CCM Serial Number : 59
Sender Chassis ID : None
Sender Management Address: None
Detect Time : 2013-11-16 09:50:52
show cfm fault
Purpose
Used to show fault MEPs.
Syntax show cfm fault {md <string 22> {ma <string 22>}}
Description
This command displays all the fault conditions detected by the MEPs contained in the
specified MA or MD. This display provides the overview of fault status by MEPs.
Parameters md – Specifies the maintenance domain name.
ma – Specifies the maintenance association name.
Restrictions
None.
Example usage:
To display cfm fault:
DES-3528:admin# show cfm fault
Command: show cfm fault
MD Name MA Name MEPID Status
----------- ----------- ----- ---------------------------
op_domain op1 1 Cross-connect CCM Received