Furthermore, a fixed set of factory settings can be copied into one or more set-ups.
Some of the advantages of having more than one set-up in the frequency converter are
• Run motor in one set-up (Active Set-up) while updating parameters in another set-up
(Edit Set-up)
• Connect various motors (one at a time) to frequency converter. Motor data for various
motors can be placed in different set-ups.
• Rapidly change settings of frequency converter and/or motor while motor is running (eg.
ramp time or preset references) via bus or digital inputs.
The
Active Set-up
can be set as
Multi Set-up
where the active set-up is selected via input on a
digital input terminal and/or via the bus control word.
NB!
FactorySet-up
cannot be used as
Active Set-up
.
0-10 Active Set-up
Option: Function:
Active Set-up
controls the motor.
Shifts between set-ups can only happen when
•the motor is coasted
OR
• the set-ups between which the shift happens are linked
to each other (see par. 0-12,
Linked Set-ups
).
If changing between set-ups that are not linked, the change will
not happen before motor is coasted.
NB!
The motor is only considered stopped when it is
coasted.
[1 ]
*
Set-up 1
Set-up 1
is active.
[2] Set-up 2
Set-up 2
is active.
[9] Multi Set-up Select the active set-up via digital input and/or bus, see par.
5-1* choice [23].
0-11 Edit Set-up
Option: Function:
The
Edit Set-up
is for updating parameters in the frequency
converter from either LCP or bus. It can be identical or different
from the
Active Set-up
.
All set-ups can be edited during operation, independently of the
active set-up.
[1 ]
*
Set-up 1 Update parameters in
Set-up 1
.
[2] Set-up 2 Update parameters in
Set-up 2
.
4. Parameter Descriptions VLT Micro Drive FC 51
14
MG.02.C2.02 - VLT
®
is a registered Danfoss trademark
4