EasyManua.ls Logo

Danfoss VLT FC 51 Series - 8-33 FC Port Parity; 8-35 Minimum Response Delay; 8-36 Max Response Delay; 4.9.5. 8-5* Digital;Bus

Danfoss VLT FC 51 Series
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13-00 SL Controller Mode
Option: Function:
[0]
*
Off Function is disabled.
[1] On SLC is active.
13-01 Start Event
Option: Function:
Select input to activate Smart Logic Control.
[0] False Enters
False
in logic rule.
[1] True Enters
True
in logic rule.
[2] Running See par. 5-4* [5] for description.
[3] InRange See par. 5-4* [7] for description.
[4] OnReference See par. 5-4* [8] for description.
[7] Out of Current Range See par. 5-4* [12] for description.
[8] BelowILow See par. 5-4* [13] for description.
[9] AboveIHigh See par. 5-4* [14] for description.
[16] ThermalWarning See par. 5-4* [21] for description.
[17] MainsOutOfRange Mains voltage is outside the specified voltage range.
[18] Reversing See par. 5-4* [25] for description.
[19] Warning A warning is active.
[20] Alarm_Trip A trip alarm is active.
[21] Alarm_TripLock A trip lock alarm is active.
[22] Comparator 0 Use result of comparator 0 in logic rule.
[23] Comparator 1 Use result of comparator 1 in logic rule.
[24] Comparator 2 Use result of comparator 2 in logic rule.
[25] Comparator 3 Use result of comparator 3 in logic rule.
[26] LogicRule 0 Use result of logic rule 0 in logic rule.
[27] LogicRule 1 Use result of logic rule 1 in logic rule.
[28] LogicRule 2 Use result of logic rule 2 in logic rule.
[29] LogicRule 3 Use result of logic rule 3 in logic rule.
[33] DigitalInput_18 Use value of DI 18 in logic rule.
[34] DigitalInput_19 Use value of DI 19 in logic rule.
[35] DigitalInput_27 Use value of DI 27 in logic rule.
[36] DigitalInput_29 Use value of DI 29 in logic rule.
[39]
*
StartCommand This event is
True
, if frequency converter is started by any
means (digital input or other).
4. Parameter Descriptions VLT Micro Drive FC 51
58
MG.02.C2.02 - VLT
®
is a registered Danfoss trademark
4

Table of Contents