PACKTRACK MODE
PackTrack Offset (direction of travel)
Enter a value used when a value must be added for proper PackTracking. The PackTrack offset
is used to fine tune the PackTrack calibration in the Y-direction (direction of travel). If after the
static calibration is complete, the bar code is still not placed on the package correctly, the
PackTrack offset parameter allows for a slight adjustment on the Y plane.
Encoder Settings
Physical Encoder
Select Disable or Enable from the drop-down list:
Disable: External encoder is disabled, and internal encoder is active
Enable: A physical encoder is connected to the Encoder input and is enabled