APPENDIX B
348
AV500/AV900 2D CAMERA
Assembly Object (04HEX – 4 Instances)
Class Attributes
Attribute ID Name Data Type Data Value Access Rule
1 Revision UINT 1 Get
2 Max Instance UINT 81 Get
Instance 0x64 Attributes (Input Instance 1)
Attribute ID Name Data Type
Default
Data Value
Access Rule
3
Input Data
Structure of:
Discrete Input Word (see
below)
B
arcode Sequence Num-
ber
Barcode Status (reserved)
Barcode Size Word
Barcode Data [UINT]
UINT
UINT
UINT
UINT
UINT [ ] varies
(up to 64)
0
0
0
0
0
Get
Discrete Input Word
Bit
0 Reader Programmable Output #1
1 Reader Programmable Output #2
2 Reader Programmable Output #3
3 Reader Programmable Output #4
4 Reader Programmable Output #5
5 Reader Programmable Output #6
6 Reader Programmable Output #7
7 Reader Programmable Output #8
8-15 Unused
Instance 0x70 Attributes (Output Instance 1)
Attribute ID Name Data Type
Default
Data Value
Access Rule
3
Output Data
Structure of:
Discrete Output Word
(s
ee below)
Last Bar
code Seq. Num
Received
UINT
UINT
0
0
Get / Set

Table of Contents