Symbologies
132
Magellan
TM
1100i
Start/Stop Character Match
This feature enables/disables the requirement that start and stop characters match.
Codabar Stitching
Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to
the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s soft-
ware, and the data will be decoded if all barcode proofing requirements are met.
START / END
PROGRAMMING BARCODES
Disable Start/Stop Char Match
DEFAULT
Enable Start/Stop Char Match
NOTE
Only functions when
Fixed Length Decoding is enabled.
START / END
PROGRAMMING BARCODES
Disable Codabar Stitching
DEFAULT
Enable Codabar Stitching

Table of Contents

Other manuals for Datalogic Magellan 1100i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 1100i and is the answer not in the manual?

Datalogic Magellan 1100i Specifications

General IconGeneral
Yaw reading angle-75 - 75 °
Decoding standards-1D + GS1 DataBar, -GS1 DataBar Composites, -GS1 DataBar Expanded Stacked, -GS1 DataBar Stacked, -GS1 DataBar Stacked Omnidirectional, -MicroPDF417, -PDF417.
Tilt reading angle0 - 360 °
Pitch reading angle-65 - 65 °
Standard interfacesUSB, RS-232
Input voltage4.5 - 14 V
Power consumption400 mA
Dimensions (WxDxH)84 x 71 x 94 mm
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight198.5 g