EasyManuals Logo

Datalogic Magellan 1100i Product Reference Guide

Datalogic Magellan 1100i
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
Symbologies
142
Magellan
TM
1100i
MSI/Plessey — continued
MSI/Plessey Stitching
Enables/disables stitching for MSI/Plessey barcodes. When parts of an MSI/Plessey label are
presented to the scanner with this feature enabled, the barcode parts will be assembled by the
scanner’s software, and the data will be decoded if all barcode proofing requirements are met.
NOTE
Only functions when
Fixed Length Decoding is enabled.
START / END
PROGRAMMING BARCODES
Disable MSI/Plessey Stitching
DEFAULT
Enable MSI/Plessey Stitching

Table of Contents

Other manuals for Datalogic Magellan 1100i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 1100i and is the answer not in the manual?

Datalogic Magellan 1100i Specifications

General IconGeneral
Yaw reading angle-75 - 75 °
Decoding standards-1D + GS1 DataBar, -GS1 DataBar Composites, -GS1 DataBar Expanded Stacked, -GS1 DataBar Stacked, -GS1 DataBar Stacked Omnidirectional, -MicroPDF417, -PDF417.
Tilt reading angle0 - 360 °
Pitch reading angle-65 - 65 °
Standard interfacesUSB, RS-232
Input voltage4.5 - 14 V
Power consumption400 mA
Dimensions (WxDxH)84 x 71 x 94 mm
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight198.5 g