Enter/Exit Programming Mode
140
PowerScan™ PD9530/PBT9500/PM9500
Codabar Start/Stop Character Set
This option specifies the format of transmitted Codabar start/stop charac-
ters
$CCBSC00(CR)
Codabar Check Character Set = ABCD/TN*E
$CCBSC01(CR)
Codabar Check Character Set = ABCD/ABCD
$CCBSC02(CR)
Codabar Check Character Set = abcd/tn*e
$CCBSC03(CR)
Codabar Check Character Set = abcd/abcd
DEFAULT
.
Codabar Start/Stop Character Match
When enabled, this option requires that start and stop characters match
DEFAULT
$CCBSM00(CR)
Codabar Start/Stop Character Match =
Don’t Require Match
$CCBSM01(CR)
Codabar Start/Stop Character Match = Require Match
.