Enter/Exit Programming Mode
142
PowerScan™ PD9530/PBT9500/PM9500
Codabar Set Length 1
This feature specifies one of the bar code lengths for Codabar Length Con-
trolCodabar Length Control. Length 1 is the minimum label length if in Vari-
able Length Mode, or the first fixed length if in Fixed Length Mode. Length
includes the bar code’s start, stop, check an
d
data characters. The length
must include at least one data character. The length can be set from 3 to 50
characters.
Table 14 provides some examples for setting Length 1. See page 283 for
detailed instructions on setting this feature.
Table 14. Codabar Length 1 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (and pad
with leading zeroes)
03 Characters 09 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODABAR LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘3’ ‘0’ and ‘9’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CCBL1
Select Codabar Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
03 = Length 1 is 3 Characters