Enter/Exit Programming Mode
Product Reference Guide
247
DISPLAY AND KEYBOARD FEATURES
Two keyboard models are available, the 4-key model and the 16-key model.
The following section contains configuration parameters that are common
and applicable to both keypad models, unless specifically labeled as "4-key
models only" or "16-key models only”.
For more items for the 16-key model, see "Additional Features for 16-key
models," starting on page 260.
Display Operating Mode
Select the operating mode of the display. Options are:
Normal Mode: Display not cleared, no echo of the code on Display.
Local Echo: Display cleared after decode, echo of the code on display.
Clear display after decode: Display is cleared after decode, no echo.
$CDIMD00\r
Normal Mode = Display not cleared
$CDIMD01\r
Local echo mode
DEFAULT
$CDIMD02\r
Clear display after decode