Enter/Exit Programming Mode 2D Global Features
176
PowerScan™ PD9530/PBT9500/PM9500
AZTEC CODE
Aztec Code Enable / Disable
Enables/disables the ability of the reader to decode Aztec Code labels.
DEFAULT
$CAZEN00(CR)
Aztec Code = Disable
$CAZEN01(CR)
Aztec Code = Enable
Aztec Code Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CAZLC00(CR)
Aztec Code Length Control = Variable Length
$CAZLC01(CR)
Aztec Code Length Control = Fixed Length

Table of Contents

Other manuals for Datalogic PowerScan PD9530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9530 and is the answer not in the manual?

Datalogic PowerScan PD9530 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Linear (1D) barcodes supported-
Standard interfacesRS-232, USB, Keyboard wedge
Connectivity technologyWired
Product colorBlack, Yellow
International Protection (IP) codeIP65
Input voltage5 V
Power consumption350 mA
Power source typeDC
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth110 mm
Width74 mm
Height212 mm
Weight330 g