Table 99. Config8. R2T + R3A(continued)
CARD TYPE SLOT PRIORITY MAXIMUM NUMBER OF CARDS
Intel (NIC: 1 Gb) QP,F1,Low Profile 1,2,3 3
Broadcom (NIC: 1 Gb) 4P,F1,Low Profile 1,2,3 3
Mellanox (NIC: NDR200) 1P,PCIe,Low
Profile
1,2,3 3
Mellanox (NIC: HDRV) 1P,Q56,Low
Profile
1,2,3 3
Intel (OCP: 25 Gb) 2P,S28 INT 1
Intel (OCP: 25 Gb) 4P,S28 INT 1
Mellanox (OCP: 25 Gb) 2P,S28 INT 1
Broadcom (OCP: 25 Gb) 2P,V2 INT 1
Broadcom (OCP: 25 Gb) 4P,V2 INT 1
Broadcom (OCP: 25 Gb) 4P,V3 INT 1
Broadcom (OCP: 25 Gb) 2P,V3 INT 1
Broadcom (OCP: 10 Gb) 4P,BT INT 1
Broadcom (OCP: 10 Gb) 2P,BT INT 1
Intel (OCP: 10 Gb) 2P,BT INT 1
Intel (OCP: 10 Gb) 4P,BT INT 1
Broadcom (OCP: 10 Gb) 2P,V2 INT 1
Broadcom (OCP: 1 Gb) 4P,BT INT 1
Intel (OCP: 1 Gb) 4P,BT INT 1
Broadcom (OCP: 1 Gb) VP,BT,V2 INT 1
FOXCONN (BOSS-N1) MONOLITHIC INT 1
FOXCONN (BOSS-N1) MONOLITHIC INT 1
Removing the expansion card risers
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4.
NOTE:
If BOSS-N1 module is installed, ensure to disconnect the BOSS-N1 power cable and Signal cable before removing
the Riser 1 cage.
CAUTION: To avoid damaging the power cable connector, press the latch on the BOSS-N1 power cable before
disconnecting.
Installing and removing system components 151